Multi-Party Paging System
Features
+EMC standard supper strong in anti-interference
+Heavy-Duty intercom multiparty communication
+ Wall mount type with door cover protection
+Outdoor and hazardous location waterproof IP66
+ 220VAC center powered and telephone station line powered
+Digital call system auto answer and auto hang up
+With Built-in amplifier and external speaker 10W-30W.
Introduction:
The “Multi-Party Talk” Paging system is designed for communication in industrial environments where high noise, corrosive atmospheres, hazardous areas and extremes of temperature, dust and humidity create hostile environments. The “Multi-Party Talk” system allows operators to both broadcast instructions over the system speakers and hold conversation with two or more people.
Operation:
To initiate communication or broadcast over the system, the operator at one of the station just push to talk. All there station ringing and auto-answer. All the other users at all other station can joins the conversation without any operation. The system allow all party simultaneous conversation without cross-talk or interference. After conversation each station will auto off to release the line. Centralized power supply box: built-in battery back 1 hours Telephone station: line powered from Centralized power supply box. Application: Quayside crane, Drilling Platform, Popular applications include elevator, power plants, TBM machine, security room, metal processing plants, mining operations, paper mills, offshore platforms, water treatment plants, and manufacturing, packaging, and processing plants.
Centralized power supply box: built-in battery back 1 hours
Telephone station: line powered from Centralized power supply box.
Technical Data
Cross Section | Cores *size | 1*6 |
Cond. Dia. | (mm) | 3.0 |
Insu. Dia | (mm) | 5.1 |
Overall Diameter (mm) | Min. | 8.0 |
Max. | 9.5 | |
Cable Weight | Approx.(kg/km) | 130 |
30°C Current Capacity in Air | (A) | 70 |
Voltage Drop | (V/A.KM) | 5.6 |
Max.DC resist .Conductor 20°C | (ohm/km) | 3.3 |
Distance(m) | Start position | End position |
10 PCL room | PCL-room | |
26 PCL room | E-room | |
26 PCL room | M-house | |
68 PCL room | Backreach shelter | |
108 PCL room | LS ground level checker cabin | |
128 PCL room | WS ground level checker cabin | |
128 PCL room | Right lashing plaltform checker cabin | |
138 PCL room | Left lashing plaltform checker cabin | |
150 PCL room | Elevator | |
215 PCL room | operator cabin |